Product Details:
Usage/Application | Diagnostics |
Material | SS |
Brand | Labsystems |
Model Name/Number | NS96 |
Voltage | 110 - 220 V |
Product Details:
Model Name/Number | NS496 |
Usage/Application | Laboratory |
Brand | Trivitron |
Weight | 15 kgs |
Operating Temperature | 15 to 35 Deg C (59 to 95 Deg F) |
Operating Humidity | 35 to 80 RH,non-condensing |
Physical Dimension | 646 mm (W) X 432 mm (D) X 356 mm (H) |
Normal input Voltage | 100 -240 VAC |
Normal AC Input Frequency | 50- 60 Hz |
Internal Voltage | 4 A at 115V,2 A at 240V |
Internal Fusing | 3 A Anti-Surge (24 V DC) |
USB Interface | Type B connection |
Safety Spec | CE MDD Directive 93/42/EEC; IEC60601-1 |
Main Menu:
Test Editor Module:
Distribution Module:
Configuration Module:
Product Details:
Usage/Application | Clinical |
Brand | Labsystems |
Model Name/Number | NS2400 |
Automation | Fully Automatic |
Voltage | 230 V |
Frequency | 50 Hz |
Revolutionary Automation in Neonatal Screening: The Labsystems Diagnostics'/ Tecan's Neonatal platform is a high throughput system intended for quantitative NS2400 AUTOMATE analysis of neonatal screening samples on 96-well microplates.
Product Details:
Brand | Trivitron |
Usage/Application | Laboratory |
Form | Liquid |
Result Time | 20-30 min |
Shelf Life | 12 Months |
Packaging Type | Box |
Product Details:
Maximum Sample Capacity | 355 circles of half inch (13mm) each |
Circle Capacity | 7580 ul per circle |
Packaging Type | Box |
Material | Nylon |
Packaging Size | 100 Sheets |
Product Details:
Brand | Labsystems |
Application | Laboratory |
Form | Cassette |
Material | Plastic |
Packaging Type | Box |
Product Details:
Brand | Trivitron |
Usage/Application | Laboratory |
Form | Liquid |
Shelf Life | 12 Months |
Packaging Type | Bottle |
Benefits:
Product Details:
Brand | Trivitron |
Usage/Application | Laboratory |
Result Time | 30 min |
Shelf Life | 12 Months |
Packaging Type | Box |
NADP+ is reduced by glucose-6-phosphate dehydrogenase enzyme (G-6-PD) in the presence of glucose-6-phosphate, and the rate of formation of NADPH is proportional to the G-6-PD activity, and is determined fluorometrically.
It is an enzymatic method for the quantitative determination of glucose-6-phosphate dehydrogenase activity from dried blood spots, with fluorometric detection.
Other Details:
Benefits:
Product Details:
Brand | Labsystems |
Usage/Application | Laboratory |
Packaging Size | 5 strip plates (12x8),480 wells 61 99 802 |
Shelf Life | 12 Months |
Packaging Type | Box |
In a 5 year study in Brazil over 285 000 neonates were screened with Labsystems Diagnostics' Neonatal Toxoplasma gondii IgM FEIA and the prevalence was found to be 1/1867.
Fluorometric enzyme immunoassay for the determination of IgM antibodies to Toxoplasma gondii from dried blood spots. This is the first Neonatal Toxoplasma screening test in the world.
Benefits:
Product Details:
Brand | Trivitron |
Usage/Application | Laboratory |
Result Time | 30 to 1 Hour |
Shelf Life | 12 Months |
Packaging Type | Box |
Bebefits:
Product Details:
Brand | Trivitron |
Usage/Application | Laboratory |
Result Time | 2 hrs 30 min |
Shelf Life | 12 Months |
Packaging Type | Box |
As a first in the world achievement, Labsystems Diagnostics has established a methodology to measure OTC, CPS1 and NAGS deficiencies on dried blood spot along with the traditional detection of ASS, ASL and ARG1 enzyme deficiencies. NeoMass AAAC for tandem MS will therefore enable detection of all urea cycle abnormalities.
Patented innovation by Labsystems Diagnostics: NeoMass AAAC innovation enables detection of all urea cycle deficiencies, including proximal abnormalities along with classical distal deficiencies measurements.
The urea cycle is a metabolic pathway occurring in the liver and kidney. Ammonia, a product of protein metabolism, is removed from circulating blood through urea cycle by conversion into urea and its elimination in urine. Urea Cycle Disorders (UCD) occurs in some inborn errors of metabolism, resulting in accumulation of nitrogenous waste which leads to vomiting, increasing lethargy, seizures, hypotonia, respiratory distress, coma, and to death if untreated. Protein restriction is the mainstay of therapy for the management of urea cycle defects.
Unique Properties of NeoMass AAAC kit – detection of OTC, CPS1 and NAGS deficiencies: Deficiencies of enzymes in the proximal part of the urea cycle have been challenging to detect in the past but the patented innovation in the new NeoMass AAAC kit changes this. As a first in the world achievement, Labsystems Diagnostics has established a methodology to measure OTC, CPS1 and NAGS deficiencies on dried blood spots along with the traditional detection of ASS, ASL and ARG1 enzyme deficiencies. NeoMass AAAC for tandem MS will therefore enable detection of all urea cycle abnormalities.
Features:
Product Details:
Usage/Application | Hospital, Clinic |
Brand | Trivitron |
Model Name/Number | NeoMass AAAC |
Packaging Type | Box, Bottle and Vial |
State | Liquid |
Product Details:
Brand | Trivitron |
Usage/Application | Laboratory |
Form | Liquid |
Result Time | 1.5 min |
Shelf Life | 12 Months |
Packaging Type | Box |
Quantitative Analysis of:
Note: Single protocol and single injection for all analytes including SUAC